Emitter Plugging Caused by Manganese Oxides in SDI Systems

(Field 3)
James P. Bordovsky and Joe Mustian

Fig. 1. SDI emitters removed from low flow rate zones.  The outer wall of the top drip tape is removed to expose Mn compounds preventing flow.Objective: The objective was to develop a method that prevents the deposition of manganese (Mn) compounds in SDI drip emitters and to reestablish uniform flow in SDI zones plugged by Mn.

Methodology: Deposits of manganese (Mn) compounds caused by Mn bacteria in the well water were plugging drip emitters and causing severe plant stress within SDI zones. The bacteria Crenothix and Leptpthix can oxidize dissolved Mn causing precipitation of manganese hydroxide. The most common approach to control Mn bacteria is by elevating the chlorine level in the well to between 400 and 500 ppm for up to 8 hours, then pumping the well to waste until the well water clears. Various attempts to unplug drip emitters in the lab and field using different types and concentrations of acids, hydrogen peroxide (H2O2), and chlorine were tried with no success. A method used to extract Mn from soil was modified and successfully used on plugged drip zones. The method involved injecting H2O2 into buffered irrigation water (pH < 7.0) and temporarily elevating the operating pressure on the drip system.

Fig. 2. Zone of SDI cotton field with plugged emitters, Helms Farm, October 2002Results: Shock treatment of water well with chlorine temporarily reduced the Mn slimes causing the emitter plugging problems. Treatment with H2O2 in buffered irrigation water increased flow rates in the most severely plugged SDI zones from 30 to 100% of the design flow rate. The risks associated with using the described unplugging procedure are unknown. The chemicals used are extremely hazardous. In addition, the effects of these materials on equipment and growing crops have not been sufficiently investigated. If deemed necessary, use of these procedures should be left to certified SDI consultants.

 

 

 

Figure 3. Comparison of design zone flow rate to actual flow rates of partially and severely plugged zones as treatments were applied to clear Mn compounds from SDI emitters, Helms Farm, 2002

Comments are closed.